Kartasasmita, Arief and Kusdiono, Widi and Virgana, Rova and Boesorie, Shanti (2017) In Vivo Emulsification Analysis of 1000 cs and 5000 cs Silicone Oil after Rhegmatogenous Retinal Detachment Vitrectomy Surgery. Open Journal of Ophthalmology, 07 (04). pp. 231-239. ISSN 2165-7408
OJOph_2017092814364715.pdf - Published Version
Download (241kB)
Abstract
Purpose: To compare in vivo emulsification of silicone oil 1000 and 5000 centistokes (cs) after retinal detachment surgery. Design: Comparative non-interventional Retrospective study. Methods: Silicone oils from patients who underwent retinal detachment surgery were investigated using Spectrophotometer UV-Vis. Spectroscopically changes determine emulsification with the time of tamponade, inflammation, patients age and severity of retinal detachment. Results: We found significant difference on absorbance (p = 0.004) between used 1000 Centi stoke (cs) silicon oil (average wave length 2.51 nm; SD: 1.575 nm) and used 5000 cs silicon oil (average wave length 0.910 nm; SD: 0.564 nm). Conclusions: In vivo emulsification was higher in silicone oil 1000 compared to 5000 cs silicone oil after vitreoretinal tamponade 8 - 12 weeks due to retinal detachment surgery. Emulsification related to higher absorbance and lower transmittance in 1000 cs silicone oil. Inflammation may become a factor affecting this condition.
Item Type: | Article |
---|---|
Subjects: | Academic Digital Library > Medical Science |
Depositing User: | Unnamed user with email info@academicdigitallibrary.org |
Date Deposited: | 06 Feb 2023 06:04 |
Last Modified: | 05 Jun 2024 09:37 |
URI: | http://publications.article4sub.com/id/eprint/596 |